1.
Rev. bras. oftalmol ; 78(4): 242-245, July-Aug. 2019.
Article in English | LILACS | ID: biblio-1013681

ABSTRACT

ABSTRACT Objective: The goal of the study is to analyze the color vision acuity pattern in undergraduates of health courses and to discuss the impact of these diseases in this population. Color deficiencies interfere significantly in the daily routine of professionals in the health area who need to discern different color hues in several situations of their everyday practice. Methods: Sixty-four volunteers, undergraduates of health courses of the Federal University of Alfenas (UNIFAL-MG), participated in the study. One man was excluded because he did not fit the inclusion criteria. Two groups were analyzed according to sex with the Farnsworth Munsell 100-Hue test. Results: There were no significant differences between the eyes and between the groups analyzed. The color vision acuity pattern is between 35 and 40, according to the Total Error Score. The gender issue does not influence the general pattern of the color vision acuity of the health courses undergraduates when those with color vision disorders are removed. Conclusion: Screenings and guidance should be given to undergraduates of health courses so that, aware of their condition of presenting some type of color disorder, they shall make the appropriate decision on which career to follow so that such limitation does not interfere with the quality of their daily life.


RESUMO Objetivo: O objetivo do estudo é analisar a acuidade visual média para cores de estudantes da área de saúde e discutir o impacto das doenças que a afetam nessa população. Deficiências cromáticas interferem de forma significativa no dia a dia de profissionais da área da saúde que necessitam de discernir diferentes matizes em diversas situações de sua prática profissional. Métodos: Participaram da pesquisa 64 voluntários, estudantes de cursos da área de saúde da Universidade Federal de Alfenas, sendo que 1 homem foi excluído por não se adequar aos critérios de inclusão. Dois grupos foram analisados, de acordo com o sexo, com o teste de Farnsworth Munsell 100-Hue. Resultados: Não houve diferenças significativas entre os olhos e entre os grupos analisados. O padrão de visão de cores encontra-se entre 35 e 40, de acordo com a Pontuação do Erro Total. A questão de gênero não influencia no padrão geral da qualidade de visão de cores de estudantes da área de saúde, quando retirados aqueles que apresentam distúrbios da visão cromática. Conclusão: Devem ser realizadas triagens e orientação para estudantes de cursos da área de saúde para que, cientes da sua condição de apresentar algum tipo de distúrbio cromático, possam tomar a decisão adequada sobre qual carreira seguir para que tal limitação não interfira na qualidade de sua vida diária.


Subject(s)
Humans , Male , Female , Students, Health Occupations , Color Vision Defects/diagnosis , Color Vision Defects/epidemiology , Health Personnel , Color Perception Tests/methods , Professional Competence , Quality of Life , Schools, Health Occupations , Visual Acuity , Vision Screening , Color Vision Defects/psychology , Diagnosis, Computer-Assisted/methods , Color Perception/physiology , Color Vision/physiology
2.
ROBRAC ; 22(60)jan.-mar. 2013. tab, ilus
Article in Portuguese | LILACS | ID: lil-681396

ABSTRACT

Objectives: The aim of this study was to evaluate the influence of the color of the resin luting cement in the final shade of minimally invasive porcelain veneers after accelerated artificial aging (AAA). Material and methods: 20 bovine teeth were collected, prepared and divided into two groups. The roots were removed and the buccal surfaces were polished to obtain a flat surface. Porcelain discs (IPS Empress Esthetic) were produced to a standardized shade (ET1) and thickness (0.6mm). The teeth and the veneers surfaces were prepared according to manufacturer recommendations. For group I (n=10), the White-Opaque (WO) base-paste was used and for group II (n=10) the Yellow (Y) base-paste. Each specimen was photocured for 60 s. The specimens were next subjected to AAA. They were submitted to color readings with a spectrophotometer in three moments: after the preparation (only the substrate), after the cementation and polymerization of the veneers and after the AAA. Were obtained values of L*, a* and b* and the total color change was calculated (?E*). Values obtained were subjected to statistical analysis in SPSS 17.0 for Windows with a significance of 0.05. Results: When comparing the cements, the Y cement showed higher ?E*, lower L* and higher b* after AAA than the WO. Conclusion: Both cements could mask the substrate color. With AAA, only the Y shade showed a ?E* clinically unacceptable, becoming more yellow (higher b*) and losing lightness (lower L*).


Objetivos: O objetivo do presente estudo foi avaliar a influência da cor do cimento resinoso na tonalidade final de facetas de porcelana minimamente invasivas, após envelhecimento artificial acelerado (EAA). Material e Métodos: 20 dentes bovinos foram coletados, preparados e divididos em dois grupos. As raízes foram removidas e a face vestibular foi polida para obter uma superfície plana. Discos de porcelana (IPS Empress Esthetic) foram confeccionados na cor ET1 e espessura de 0,6 mm. Os dentes e as superfícies dos discos foram preparados de acordo com as recomendações do fabricante. Para o grupo I (n=10) foi usado o cimento resinoso White-Opaque (WO) pasta-base, e para o grupo II (n-10) utilizou-se o Yellow (Y) pasta-base. Cada espécime foi fotopolimerizado por 60 s. Os espécimes foram então submetidos ao EAA. Eles foram submetidos a leituras de cor com auxílio de um espectro fotômetro em três momentos: após o preparo (apenas o substrato), após a cimentação e polimerização das facetas e após o EAA. Foram obtios valores de L*, a* e b* e o total da variação de cor foi calculado (?E*). Os valores obtidos foram submetidos à análise estatística no SPSS 17.0 para Windows, com nível de significância de 0,05. Resultados: O cimento Y apresentou maior ?E*, menor L* e maior b* após o EAA em comparação com o WO. Conclusão: Ambos os cimentos têm capacidade de mascarar a cor do substrato. Com o EAA, apenas o Y apresentou um valor de ?E* inaceitável clinicamente, se tornando mais amarelo (maior b*) e perdendo luminosidade (menor L*).

3.
Rev. bras. oftalmol ; 67(5): 214-219, set.-out. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-497324

ABSTRACT

OBJETIVO: Avaliar a condição ocular em população de trabalhadores de uma indústria metalúrgica paulista. MÉTODOS: Amostra de 2516 funcionários de uma fábrica na cidade de São Paulo foi submetida a uma avaliação oftalmológica como exame ocupacional periódico. Foi aplicado um questionário e realizado o exame de acuidade visual (Snellen) e teste de Ishihara. Os funcionários com acuidade visual menor que 0,7 ou com diferenças maior que duas linhas ou que apresentassem alguma queixa ocular, passaram por avaliação complementar (biomicroscopia, refração, tonometria e fundo de olho). Prescreveu-se óculos conforme indicação. RESULTADOS: Houve predomínio do sexo masculino (62,5 por cento) e faixa etária de 20 a 29 anos (41 por cento). A maioria não apresentava antecedentes oculares (97,6 por cento) ou sistêmicos (96,6 por cento).A acuidade visual estava acima de 0,7 em 95,5 por cento dos olhos e 84 por cento não utilizavam correção. O diagnóstico final foi exame normal em 55 por cento dos casos, presbiopia em 13.6 por cento, astigmatismo miópico em 10 por cento e hipermetrópico em 7,7 por cento dos indivíduos. Baixa visão foi encontrada em 2,4 por cento, cegueira unilateral em 0,4 por cento, não havendo casos de cegueira ou de deficiência visual entre os trabalhadores. As principais causas de baixa visão foram erros refrativos e ambliopia. CONCLUSÃO: A maioria dos funcionários da indústria pesquisada apresentava exame oftalmológico normal e nenhum deles apresentava cegueira bilateral.


PURPOSE: To evaluate the ocular condition in a brazilian ironmaster industry. METHOD: A prospective study was conducted in 2516 employees from an ironmaster brazilian industry in São Paulo city, Brazil. A questionnaire was applied and visual acuity and Ishihara test were performed in every individual. A complete ophthalmic evaluation (slit lamp examination, fundoscopy, tonometry and refractometry) was done when the visual acuity was worse than 0.7 or when the worker had a greater diference between the eyes (more than two lines) or when there were ocular complains. Glasses were prescribed when necessary. RESULTS: Most of the evaluated employees in this industry was male (62.5 percent), ageing from 20 to 29 year old (41 percent). Visual acuity was normal in 95.5 percent of the eyes.The majority of the individuals (84 percent) did not need glasses prescription. Fifty-five percent of the employees were considered as normal eye carriers, 13.6 percent presented presbyopia, 10 percent presented myopic astigmatism and 7.7 percent hyperopic astigmatism. Visual impairment was present in 2,4 percent and blindness in one eye of 0,4 percent of the studied individuals. The main cause of visual impairment was refractive errors and amblyopia. CONCLUSION: The majority of the employees, in this particular industry, presented with a normal ophthalmic examination. None of them had bilateral blindness.

4.
Arq. bras. oftalmol ; 71(4): 585-588, jul.-ago. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-491895

ABSTRACT

As autoras relatam dois casos de discromatopsia hereditária e discutem a eficiência dos testes cromáticos no diagnóstico de uma discromatopsia. Os pacientes foram reprovados em diferentes concursos públicos federais por apresentarem diagnóstico de discromatopsia hereditária pelo teste de Ishihara. Submeteram-se a exame oftalmológico, com resultados dentro da normalidade. Procuraram novo parecer para melhor caracterização da sua discromatopsia. Não havia sintomas relacionados à deficiência. Os testes Panel D15 simples, D28 de Roth mostraram-se normais e o D15 dessaturado confirmou deutanomalia no caso 1. No segundo caso os testes de comparação mostraram alterações sem significado cromático. O diagnóstico de uma discromatopsia é muito complexo. As autoras destacam a importância de realização de testes de visão cromática complementares ao teste de Ishihara para diagnóstico de uma discromatopsia.


The authors describe two cases of hereditary dyschromatopsia and discuss the efficiency of the color vision tests. The patients were disapproved in different federal public examinations because Ishihara's test diagnosed hereditary dyschromatopsia. Ophthalmological evaluation was normal. No symptoms related to dyschromatopsia were presented. Panels D15 and Roth D 28 were normal. Desaturated D 15 showed deuteranomaly in case one. In the second case the comparative color vision tests showed nonspecific disorder. The diagnosis of dyschromatopsia is complex. The authors recommend comparative color vision tests to complement the Ishihara test for a better understanding of the color deficiency.


Subject(s)
Adolescent , Adult , Humans , Male , Color Perception Tests/standards , Color Vision Defects/diagnosis , Color Perception Tests/methods , Color Vision Defects/genetics
5.
Arq. bras. oftalmol ; 70(6): 1001-1005, nov.-dez. 2007. ilus, graf
Article in Portuguese | LILACS | ID: lil-474110

ABSTRACT

OBJETIVO: Avaliar a discriminação de cores em profissionais da área técnica de empresa de material fotográfico. MÉTODOS: Foram incluídos 47 profissionais (37 homens) com idades variando de 18 a 41 anos (média 27,2 ± 5,6 anos), alocados em área técnica especializada em calibração e assistência de máquinas de revelação de fotos em 1 hora. O tempo de trabalho nesta atividade variou de 1 mês a 18 anos. O grupo controle constituiu de 22 voluntários (5 homens) com idades variando de 18 a 55 anos (Média 25,0 ± 10,6 anos). A discriminação de cores foi avaliada com o teste Farnsworth-Munsell 100-Hue. Os critérios de inclusão para os dois grupos foram: acuidade visual com a melhor correção óptica e > 0,1 logMAR, fundo de olho normal, ausência de doenças hereditárias, sintomas visuais ou cirurgia ocular prévia. RESULTADOS: Vinte e quatro (51 por cento) profissionais do laboratório fotográfico apresentaram discriminação superior, comparados a 18 por cento dos voluntários. Vinte (42 por cento) apresentaram discriminação de cores dentro da média e 3 (7 por cento) apresentaram discriminação inferior. O índice de erros foi estatisticamente menor no grupo de profissionais quando comparado ao grupo controle (T=968.000, P=0,011). Não houve correlação entre o tempo de atividade na profissão e os resultados da discriminação de cores. CONCLUSÕES: Os profissionais da área técnica da empresa fotográfica mostraram discriminação de cores superior à do grupo controle.


PURPOSE: The objective of this study was to evaluate chromatic discrimination in employees of a photographic laboratory. METHODS: A total of 47 professional employees of the technical area devoted to calibration and technical assistance for one-hour photo machines (37 men), aged 18 to 41 years (mean of 27.2 ± 5.6 years). The period working in this function ranged from one month to 18 years. Twenty-two normal volunteers (5 men) aged 18-55 years (mean of 25.0 ± 10.6 years) were tested as a control group. Color discrimination was evaluated by the Farnsworth-Munsell 100-Hue test. The inclusion criteria were visual acuity > 0.1 logMAR, normal fundus, absence of hereditary eye disease, absence of visual symptoms or ocular surgery. RESULTS: Twenty-four people (51 percent) of the professional group presented superior color discrimination when compared to 18 percent of the control group. Twenty people (42 percent) presented average discrimination and 3 (7 percent) presented inferior discrimination. Color vision discrimination was statistically better in professionals when compared to controls (T=968.000, P=0.011). There was no correlation between the period working in the function and color discrimination. CONCLUSIONS: Technical professionals working in a photographic laboratory showed better color discrimination than controls.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Color Perception/physiology , Laboratories , Photography , Case-Control Studies , Color Perception Tests/methods , Models, Statistical , Time Factors , Visual Acuity
6.
Arq. bras. oftalmol ; 70(2): 259-269, mar.-abr. 2007. ilus, graf
Article in Portuguese | LILACS | ID: lil-453166

ABSTRACT

OBJETIVO: Avaliar a freqüência de discromatopsias através da 4ª edição do teste pseudoisocromático HRR (Hardy, Rand and Rittler) entre a população indígena masculina da aldeia Lalima, etnia Terena, na região de Miranda-MS. MÉTODOS: Foram realizadas viagens à aldeia Lalima em Miranda-MS, nos meses de janeiro e fevereiro de 2005. As viagens para realizar os exames só foram iniciadas após o projeto ter sido avaliado e aprovado pelos Comitê de Ética e Pesquisa da UFMS, Comitê Nacional de Ética e Pesquisa, Fundação Nacional do índio e do cacique da aldeia Lalima. O teste HRR foi aplicado em 226 índios após terem sido submetidos a exame oftalmológico para detecção de anormalidades que pudessem comprometer a aplicabilidade do teste. O teste foi realizado sob luz natural, em dias ensolarados, sem incidência direta de sol. O teste foi aplicado e interpretado pelo mesmo examinador em todos os índios. RESULTADOS: Realizaram-se 226 exames (60,1 por cento) de uma população de 376 homens entre 10 e 45 anos de idade, que vivem na Aldeia Lalima. Não foi encontrado nenhum caso de discromatopsia na população examinada com o teste HRR. CONCLUSÃO: O resultado do presente estudo mostra a baixa prevalência de discromatopsia nesta população indígena de etnia Terena, uma vez que não se detectou nenhum caso de discromatopsia na população estudada, sendo a prevalência de discromatopsia entre homens caucasianos de 6 a 8 por cento. A ausência de discromatopsia na população estudada, no entanto, deve ser mais bem avaliada tentando aumentar o tamanho da amostra, utilização de outros testes e, principalmente, por estudos genéticos para verificar os genes codificadores dos fotopigmentos para melhor compreensão das condições relacionadas à visão de cores dessa comunidade indígena.


PURPOSE: to evaluate the frequency of dyschromatopsias among the 10 to 45-year-old male Indian population of Lalima village, Terena ethnicity, in Miranda-MS, using the fourth edition of the pseudoisochromatic HRR test (Hardy, Rand and Rittler). METHODS: Lalima village in Miranda-MS was visited in January and February 2005. The visits only occurred after the approval of the project by the Committee of Ethics and Research of UFMS, by the National Committee of Ethics and Research, by the Indian National Foundation, and by the chief of Lalima village. The test was applied in 226 Indians who had been previously submitted to ophthalmologic examination for the detection of abnormalities that could doubt the applicability of the test. The test was performed under natural illumination, in sunny days, however with no direct sunlight. The test was applied and analyzed by the same experimenter in all the Indians. RESULTS: Two hundred and twenty-six men were examined (60.1 percent) of the total male population of 376 individuals between 10 and 45 years old who live in Lalima village. No cases of dyschromatopsia were found in this population examined with the HRR test. CONCLUSIONS: Once it is known that incidence of dyschromatopsias among the white male Caucasian population is about 6-8 percent, the results of the present study indicate a low prevalence of dyschromatopsias in this Indian population of Terena ethnicity, since no cases were detected in the examined sample. Other studies using different methods must be made to reinforce the present results. It would also be interesting to genetically examine this population and verify the genes that code for photopigments.


Subject(s)
Humans , Male , Child , Adolescent , Adult , Middle Aged , Color Perception Tests/methods , Color Vision Defects/epidemiology , Population Groups , Age Distribution , Brazil/epidemiology , Color Vision Defects/diagnosis , Color Vision Defects/ethnology , Lighting , Photic Stimulation , Prevalence , Reproducibility of Results , Statistics
SELECTION OF CITATIONS
SEARCH DETAIL